RM-1310:  

The characteristics of this instrument are as follows:
1. Previous value comparison
Compare the previous bottom dead point value with the current bottom dead point value. By comparing the previous values, the error in the environmental characteristics of the sensor can be ignored.
Detected scrap jumping on the punch, causing the punch to stop operating.
2. Automatic apposition
When the target reaches a certain distance from the sensor, it automatically performs bottom dead center monitoring in the same position. No need to locate the sensor.
3. Large digital display (compared to the predecessor of this instrument)
Using large digital displays to monitor values·The variable difference display is more prominent.
4. Using key switches (compared to the predecessor of this instrument)
It is easier to adjust the monitoring value after using the key switch. Use the "▲" and "▼" buttons to adjust.
5. Improve monitoring accuracy (compared to the predecessor of this instrument)
The monitoring resolution ranges from ± 5 μ Increase m to ± 1 μ M. The monitoring value setting range is 45 μ Increase m to 99 μ M.
6. Detect sensor disconnection (new feature)
Sensor disconnection can be detected.
7. Cycle monitoring
If the required time is more than twice that of the previous cycle (abnormal sensor installation), a stop signal of about 1 second will be issued.
8. Using the number of rotations
Range: 30-3000 min-1 (spm)
※ Please consult our company's business technology department before reaching 30 min-1 (spm).

Control principle:

When there is a scrap jumping above or below the material with a spring mold, the scrap is flattened, and about 20-40% (depending on the material) of the thickness remains, causing a change in the position of the discharge plate.

Compare and detect this change with the usual value.

This machine compares the displacement variables of each stroke and is not affected by changes in pressure or temperature rise of the machine.

This machine uses a microprocessor to only capture the bottom dead center and is not affected by the unloading plate or spring pushing.

Specifications:

Specification/Name Model NEW SELBER V RM-1310

Measurement principle method Eddy current loss method, RS-833H

Deviation display ± 99 μ MLED value 2 digits

Monitoring value display 99 μ MLED value 2 digits

Monitoring value resolution ± 1 μ M

Repetitive precision 1 μ M

Abnormal handling: The abnormal light is on and the output is stopped

Stop output when the response speed is within 12 msec

Power AC 100V~230V, 50/60Hz, below 8VA

Operating temperature range: 0-50 ℃ (no condensation)

Maximum usable rotation rate 30-3000 min-1 (spm)

Sensor distance 1.2 ± 0.3mm

Output [stop input] relay contacts (A, B contacts) max.AC250V 2A

Input [RESET input] ・ [Start input] No voltage contact input, NPN collector open circuit

Connecting cable length sensor -10cm connecting cable -3m

Size 50 (W) × 110 (H) × 120 (D) mm (excluding protrusions on the mounting plate)

 

RM-2412:

The automatic punch press lower dead center monitor NEW SELBER RM-2412 (2-channel specification) RM-2414 (4-channel specification) tests the lower dead center position of the unloading plate and detects the waste material jumping up.

This machine can track the speed of 4000min-1 and is the most suitable waste skip detector for high-speed precision punching machines.

Specialties:

●The punching length of the stamping machine corresponds to 4 millimeters. (Old models correspond to 8mm)

●Equipped with sensor correction function.

●Compared to the appearance of older models (MB, MXx2), it has been reduced in size by half.

●Can perform high-precision detection. The decomposition energy is 0.5 microns.

●Equipped with the first bounce detection function. (First rebound automatic detection function)

●The brightness of the display has increased to about four times that of the old model. It is also clearly visible in the distance.

●When the fault occurs, the display will flicker on and off. It can be easily distinguished from afar.

Control principle:

Bottom Dead Center Monitoring (B.D.C): Generally, the position of the discharge plate changes when the waste material jumps up in the discharge plate mold.

Detect the displacement of the bottom dead center and detect the scrap jumping up.

When the first rebound monitoring (1st BOUND) spring pressure is extremely high or there is a gap adjustment gasket in the mold that generates waste material that jumps up, the waste material will be flattened at the bottom dead center position and difficult to detect.

At this point, before the waste is flattened, the bottom dead point of the first rebound between the discharge plate and the waste is monitored for the waste to jump up.

The monitoring value BX detects the difference between the previous bottom dead center value and the current value (bottom dead center displacement variable).

Set the limit of this variable to monitor for scrap jumping.

 

RM-7302,7304:  

The color graphic display can observe real-time changes in the dead center. USB memory card can continuously record dead center data. Beneficial for traceability. Featuring high-speed traceability, achieving high reliability with image display and the ability to quickly trace for 2000 min-1 (spm). The original model 1300 min-1 (spm) has a visually distinct monitoring screen using a 5.7 inch LCD display. The numerical value and waveform are easy to observe. Real time changes in the slider can be monitored. By successfully using a new punch, it is possible to follow up on molds and unloading actions that can only be judged by numerical values up to now, as well as sensors and molds. Collecting data/using a computer for simple processing can extract and store dead point value data externally. Record data using a vendor USB storage card, making it easy to carry to the site after recording. The large capacity 128M memory card can record approximately 5 million strokes, and the recorded data is saved in CSV format and can be processed using Excel. Processing data in the office can be used for traceability.
Specifications:

Specification/Name New SELBER GX Bottom Dead Center Absolute Value Monitoring Combination/Model RM-7302, Sensor Input 2ch

One of the sensors RS-833H.RS-903H

Test range 600-2000 μ M

Setting range 800~1600 μ M

Resolution 1 μ M

Straightness ± 3% of F.S. (RS-833H 1200 μ M)

Colorful TFT LCD 5.7-inch 320 × 240dot

Backlight life below 50000 hours

Monitoring standard value/monitoring comparison previous value switch

Set upper limit monitoring. Switching between lower limit monitoring

± 99 compared to standard value μ M1 interval 1 μ M)

Sampling number 1-100

Cut number 0-100

Switching between detecting sensor faults and detecting sensor faults

Data recording dead point values for channel 1 or channel 2 data output

 

RM-2704:

characteristic  
 
  • It can correspond to a high-speed punch press of 2500 min-1 (spm).
  • Equipped with standard equipment sensors for 12V power output.
  • Separation, contact detection, 3-channel synchronization, memory detection, 2-channel synchronization
  • (Set the synchronization and memory detection channels as separation and contact detection, with a maximum of 7 channels available)
  • The signal input is the corresponding contact and PNP/NPN transistor · collector open circuit output.
  • Compared to the original model (MB+MM), the installation space is half smaller.
  • The time signal corresponding to the switch is equipped with a low-speed time filter circuit.
  • The display brightness is increased by four times compared to the original model. You can also see clearly from a distance.
  • The installation size is the same as BX (RM-2412).